TOSHIBA DT01ACA200 Data Recovery

The system BIOS was unable to detect the TOSHIBA DT01ACA200 hard drive due to a power surge. A power surge can logically damage your computer hard disk drive.

TOSHIBA DT01ACA200 Data Recovery

PRODUCT DESCRIPTION

  • Capacity: 2 TB
  • Speed: 7,200 RPM
  • Cache: 64 MB
  • Interface: SATA 6 Gbit/s
  • Form Factor: 3.5-inch

Although this hard disk drive is branded as Toshiba, it belongs to the Hitachi drive family 7210DLE6.

A power surge can cause the read/write heads on your hard drive to crash, seizure of the motor or hard drive platter damage. If this happens to you, our Toshiba hard drive data recovery engineers can help you to retrieve your critical data as in this case. We are experts to recover your data from Toshiba’s DT01ACA series of 7,200 rpm 3.5-inch hard disk drives [DT01ACA300 / DT01ACA200 / DT01ACA100 / DT01ACA050].

TOSHIBA DT01ACA200 Repair DT01ACA200 Repair & Data Recovery

Model : TOSHIBA DT01ACA200
Serial : X3NELE3GS
Firmware : MX4OABB0
Capacity : 1 863.02 GB (3 907 029 168)

Loading modules table…………………………………………. : Ok
Loading the table of “open” modules…………………………….. : Ok

Test : HDD resources backup
Folder: C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\HITACHI-IBM-ARM\7210DLE6\TOSHIBA DT01ACA200-MX4OABB0-X3NELE3GS\Data\SABackup\

ROM reading……………………….. : Ok
Reading ROM to file (ROM\ROM.bin)………………………………. : Ok

Reading NV-RAM to file (NV-RAM\…)…
NV-RAM.nvr…
NV-RAM_0.nvr…
NV-RAM_1.nvr…
NV-RAM_2.nvr…
NV-RAM_3.nvr…
NV-RAM_4.nvr…
Reading NV-RAM to file (NV-RAM\…)…………………………….. : Ok

Off-line start resources
Main modules table……………………………………………. : Ok
“Open” modules table………………………………………….. : Ok

Reading modules to profile folder
Folder: C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\HITACHI-IBM-ARM\7210DLE6\TOSHIBA DT01ACA200-MX4OABB0-X3NELE3GS\Data\SABackup\Modules\

Module RPSH Copy 0…………………. : Ok
Module RPSH Copy 1…………………. : Ok
Module USAG Copy 0…………………. : Ok
Module USAG Copy 1…………………. : Ok
Module RAMI Copy 0…………………. : Ok
Module RAMI Copy 1…………………. : Ok
Module RAM0 Copy 0…………………. : Ok
Module RAM0 Copy 1…………………. : Ok
Module PSHT Copy 0…………………. : Ok
Module PSHT Copy 1…………………. : Ok
Module RDMT Copy 0…………………. : Ok
Module RDMT Copy 1…………………. : Ok
Module RPOP Copy 0…………………. : Ok
Module RPOP Copy 1…………………. : Ok
Module SECI Copy 0…………………. : Ok
Module SECI Copy 1…………………. : Ok
Module SECB Copy 0…………………. : Ok
Module SECB Copy 1…………………. : Ok
Module ZONE Copy 0…………………. : Ok
Module ZONE Copy 1…………………. : Ok
Module SRVP Copy 0…………………. : Ok
Module SRVP Copy 1…………………. : Ok
Module SRVM Copy 0…………………. : Ok
Module SRVM Copy 1…………………. : Ok
Module CHNM Copy 0…………………. : Ok
Module CHNM Copy 1…………………. : Ok
Module IDNT Copy 0…………………. : Ok
Module IDNT Copy 1…………………. : Ok
Module SMRT Copy 0…………………. : Ok
Module SMRT Copy 1…………………. : Ok
Module SERL Copy 0…………………. : Ok
Module SERL Copy 1…………………. : Ok
Module IOPS Copy 0…………………. : Ok
Module IOPS Copy 1…………………. : Ok
Module SSLD Copy 0…………………. : Ok
Module SSLD Copy 1…………………. : Ok
Module SCTH Copy 0…………………. : Ok
Module SCTH Copy 1…………………. : Ok
Module FEAT Copy 0…………………. : Ok
Module FEAT Copy 1…………………. : Ok
Module CNFG Copy 0…………………. : Ok
Module CNFG Copy 1…………………. : Ok
Module WWNM Copy 0…………………. : Ok
Module WWNM Copy 1…………………. : Ok
Module RPSP Copy 0…………………. : Ok
Module RPSP Copy 1…………………. : Ok
Module SPTR Copy 0…………………. : Ok
Module SPTR Copy 1…………………. : Ok
Module ABLP Copy 0…………………. : Ok
Module ABLP Copy 1…………………. : Ok
Module DBGC Copy 0…………………. : Ok
Module DBGC Copy 1…………………. : Ok
Module ALSM Copy 0…………………. : Ok
Module ALSM Copy 1…………………. : Ok
Module ATIR Copy 0…………………. : Ok
Module ATIR Copy 1…………………. : Ok
Module AVZN Copy 0…………………. : Ok
Module AVZN Copy 1…………………. : Ok
Module CGDF Copy 0…………………. : Ok
Module CGDF Copy 1…………………. : Ok
Module PID1……………………….. : Ok
Module PID2……………………….. : Ok
Module PIDM……………………….. : Ok
Module MFGP……………………….. : Ok
Module MFGT……………………….. : Ok
Module DMP1……………………….. : Ok
Module SDM1……………………….. : Ok
Module SVLG……………………….. : Ok
Modules reading completed
Saving modules by copies………………………………………. : Ok

Logical scan
****************************************************************
Initial LBA……………………….. : 0
Final LBA…………………………. : 3 907 029 167
Data exchange mode…………………. : UDMA133
Surface verification……………….. : Yes
Random read……………………….. : Yes
Cycling number…………………….. : 1000
Writing…………………………… : No
Reading…………………………… : No
HDD cache RAM test…………………. : No
Scan direction…………………….. : Forward
Pass count………………………… : 1
Save defects………………………. : No
Don`t search sector where error occured. : No
HDD timeout……………………….. : 200 ms.
One LBA commands timeout……………. : 30 ms.
****************************************************************

Pass……………………………… : 1

Test……………………………… : Surface verification
Status……………………………. : Skip